HEKA Elektronik are a leading manufacturer of electrophysiology and electrochemistry instrumentation as well as appropriate acquisition and control software.  The current range of patch clamp amplifiers includes the classic EPC7, the EPC8, the EPC800 USB and computer controlled EPC10 with USB2.0 connection.  The technology present in the EPC8 has now led to the development of a dedicated voltammetric amplifier, the EVA8.  HEKA also offer a 2 or 3 electrode voltage clamp amplifier for xenopus oocyte recording.

 

Digitimer also supplies a range of accessories for the HEKA amplifiers, including pipette holders, o-rings and gold pins - please contact us for details.

  


EPC10 USB Patch Clamp Amplifier

The flagship of the range, the EPC10 shares many of the features of its predecessor, the EPC9, but also possesses many enhancements.  The EPC10 is now integrated with the LIH 8+8 data acquisition interface, which features a USB2.0 connection.  EPC10 amplifier control and data acquisition is handled by HEKA PatchMaster software.  Detailed information on software compatibility.

Major Features Include:


- Full computer control
- Automatic self test and calibration
- Automatic compensation of capacitance and Rs
- Integrated with LIH 8+8 acquisition interface featuring USB2.0 host interface connection
- Ultra-slim headstage design with improved noise performance
- True current clamp capabilities
- Low frequency voltage clamp
- Digital and telegraphing outputs

- NEW "Red Star" headstage (also available as an accessory) features lower noise characteristics


EPC10 Double, EPC10 Triple & Quadro USB Patch Clamp Amplifiers

The EPC10 double, triple and Quadro are the perfect instruments for performing patch clamp recordings from up two 4 cells.  Each amplifier is controlled independently through HEKA PatchMaster software.  Detailed information on software compatibility.

Major Features Include:


- Full computer control
- Automatic self test and calibration
- Automatic compensation of capacitance and Rs
- Integrated with LIH 8+8 acquisition interface(s) featuring USB2.0 host interface connection
- Complete control of each amplifier and optimized noise performance
- Holding potential range of +/- 1000 mV
- Digital and telegraphing outputs


EPC10 "Plus" Patch Clamp Amplifiers - No Longer Available

The EPC 10 PLUS is a fully computer controlled patch clamp amplifier with a built-in high-end interface board. Continuing the tradition of providing the world's best electrophysiology amplifier, the EPC 10 PLUS has all the features of the EPC 10; but it goes much further in offering many improvements with respect to data acquisition capabilities. The EPC 10 PLUS features the ITC-18 interface, with eight 18-bit AD converters with a clock rate of 200 kHz (aggregate). The premium sampling parameters make the EPC 10 PLUS most suitable for multi-channel and high-resolution recordings.

 

   

Major Features Include:


- Full computer control (Mac and Windows based)

- Can be used with PatchMaster on Windows operating systems, on MacOS 9 and Mac OS X.

- Automatic self-test and calibration

Automatic Capacitance neutralization

- Capacitance tracking

- Automatic leak subtraction

- Optimized, built-in interface

- Integration with the ITC-18 AD/DA interface to the host computer

- Ultra slim-line headstage design with improved noise performance

- True Current Clamp capabilities

- Low Frequency Voltage Clamp

- Digital outputs & telegraphing inputs

- Integration of hardware and software eliminates compatibility problems on Windows operating systems.

- True noise measurements from 100 Hz to 15 kHz

- Suitable for single-channel and whole-cell measurements, loose patch experiments, capacitance measurements, recordings from plant cells and organelles, and studying reconstituted channels in artificial membranes.


NEW  EPC800 USB Patch Clamp Amplifier

HEKA is proud to introduce a manually controllable patch clamp amplifier with analog telegraphing outputs for Gain, Filter Bandwidth, Amplifier Mode and C-Slow. The EPC 800 USB allows third-party acquisition software (e.g. IGOR, Labview, pCLAMP) to read the status of these amplifier settings while recording data.
The EPC 800 USB features automatic compensation routines for Vp-Offset, C-fast and C-slow, includes the low noise "red star" headstage and offers the a fast true current clamp circuitry for accurate recording of fast neuronal action potentials.

 

Improvements in comparison to the EPC 8:


- Telegraphing outputs for Gain, Bandwidth, Mode & C-Slow
- Automatic Vp-Offset, C-Fast & C-Slow compensation with the simple push of a button
- Improved current monitor filters
- USB 2.0 communication for software control of all amplifier functions
- Low Frequency Voltage Clamp Mode (LFVC)
- CC+Bridge Mode
- Improved RS Comp Range


EPC8 Patch Clamp Amplifier

The direct descendent of the EPC7 allows digital control of gain, mode and filtering.  The EPC8 features a holding potential range of ±500 mV, a low gain range (for currents up to 2 µA) and a number of other improvements over the EPC7.  This amplifier can be used with the Instrutech ITC-16, ITC-18 & LIH 8+8 interfaces and HEKA Software or other hardware/software combinations.  Detailed information on Heka software compatibility.

Major Features Include:


- Manual control using knobs & switches on the front panel
- Optional digital control of some functions by the computer
- Holding potential range of +/-500 mV
- +/-200 mV pipette offset
- A low gain range allows currents up to 2 µA
- Built-in 'phase tracking' capabilities
- Variable hardware filters
- C-Slow compensation (0-1000 pF, calibrated)


EPC7 "Plus" Patch Clamp Amplifier

The EPC7 represents roughly the seventh in the series of patch clamp designs in use in the Göttingen laboratories of Neher and Sakmann since their initial experiments. The EPC7 is produced by HEKA, the first manufacturer of patch clamp amplifiers in the world. The EPC7 is the "classic" patch clamp amplifier and includes all features necessary to perform patch-clamp experiments of highest quality. Due to its excellent design the EPC7 is still manufactured, to this day, with few changes.  This amplifier can be used with the Instrutech ITC-16, ITC-18 & LIH 8+8 interfaces and HEKA Software or other hardware/software combinations.  Detailed information on software compatibility.

Major Features Include:


- Manual control with knobs & switches on the front panel
- Manual adjustment of the pipette offset (+/- 50 mV)
- Gain: x0.5 to x1000 mV/pA
- Bandwidth: 100 kHz (medium range), 60 kHz (high range)
- Butterworth or Bessel filter
- Manual adjustment of the capacitance compensation
- Noise monitor facilities
- Hardware controlled holding potential with a total range of +/-200 mV
- Manual adjustment of Rs compensation


NEW  HEKA iTEV 90  Multi-Electrode Voltage Clamp Amplifier

HEKA is pleased to release its first fully computer controlled multi-electrode clamp amplifier for two/three electrode Xenopus oocyte recording. The iTEV 90 amplifier is a complete two-electrode voltage and current clamp amplifier providing the option to add a third electrode.

   
Major Features Include:

- Fully computer controlled, e.g. gain, stimulus filter, filter and clamp gain can be set from the software.
- Full data integrity; amplifier & acquisition parameters are stored with the data to allow review & analysis later
- Automated calibration and testing algorithms
- Easy to use software interface provided by PATCHMASTER
- Automated clamp parameter adjustment
- Automated transient compensation
- Slim headstage design
- Dove tail mounting adapter or base plate allow easy mounting on your manipulator
- Optional 3rd electrode for use as:-

- Extracellular field compensation electrode

 -Additional intracellular current injection in order to further increase the clamp speed


HEKA EVA8 Voltammetric Amplifier

The EVA8 allows exocytotic events such as neurotransmitter release to be monitored voltammetrically.  Besides high resolution recordings of ion concentration this unit can be used in studies of quantitative determination of organic and inorganic compounds, determination of electron transfer and reaction mechanism, studies of oxidation and reduction process.    This amplifier can be used with the Instrutech ITC-16 and ITC-18 interfaces as well as the LIH 8+8 and HEKA Software or other hardware/software combinations.  Detailed information on software compatibility.

Major Features Include:


- Manual or computer controlled
- Capacitance compensation
- Current sensitivity: 5 mV/nA to 1 V/pA
- +/- 2V command ranges
- 17 current output gain ranges
- 7 Pole Bessel Filter adjustable from 0.1 - 30 kHz in 11 steps
- Two external command ranges for 1 V or 2 V at the headstage.
- Three gain ranges
- Largest measurable currents:

200 pA (50 GOhm, range)
20 nA (500 MOhm, range)
2 µA (5 MOhm, range)


HOME > RESEARCH > PATCH CLAMP & VOLTAMMETRIC AMPLIFIERS


[Latest News]    [Newsletter]    [Downloads]    [Contact Us]    [Support]    [Search]   [Website Guide]    [Privacy]    [Company Information]

 

© 2011 Digitimer Limited - "Digitimer" and "NeuroLog" are registered Trade Marks of Digitimer Ltd.
Product Specifications are subject to change without prior notice
Subscribe to E-News

Join us on Facebook